afPtLteFdd Release Notes
======================


This library supports LTE FDD testing in the PXI Maestro measurement system. It
can not be used in isolation.

In order to use this component the other required components are:

1:    The PXI Maestro core library.

2:    A PXI Maestro DUT Connection Control library that supports a broadcast downlink
      signal and a switched uplink signal and implements the following API functions
      defined in afPtDutConnectionControl.h:
        afPtDcc_GetVersion
        afPtDcc_Create
        afPtDcc_Destroy
        afPtDcc_PortCount_Get
        afPtDcc_PortName_Get
        afPtDcc_NameLength_Max_Get
        afPtDcc_Capability_Get
        afPtDcc_PortLimits_Get
        afPtDcc_Connect

3:    A PXI Maestro DUT Driver library that supports LTE FDD and implements:
        The Core DUT Driver API defined in afPtDutDriverInstance.h
        The LTE FDD DUT Driver API extensions defined in afPtLteFddDutDriver.h
    Has the ability to directly control the Tx Power of the device and disable power control

4:    A 301X/302X signal generator combination.

5:    A 301X/303X digitizer combination with option 107 and 207.

Additionally, in order to make power supply current measurements, version 1.3.0 or later of
the PXI Maestro core library must be used and a power supply plugin dll that implements
afPtPSUControl_PSUMeasurementsSupported_Get and afPtPSUControl_DoPSUMeasurements must be
supplied.


The following list of software releases is in date order, with the latest at the top.


** IMPORTANT **
Please note that this measurement module has been superceded by the LTE Uplink measurement module
which should be used for all new test plans.

Latest Release 
==============

Version 1.8.0


Version 1.8.0
=============
    Updated to support new analysis library API - no functional change.

    
Version 1.7.0
=============
    Fixed a stability issue in the use of the signal generator to provide a downlink signal.

    Fixed an issue whereby the DUT(s) were always forced to resync - even when the 
    baseband signal had not been disturbed. This change allows some dut driver implementations 
    to better optimise the synchronisation and handover operations.

    Fixed an issue where errors reported from the Dut Connection Control were ignored when 
    connecting a DUT to the digitizer.
    
    Added the ability to measure Rx Power on both main and diversity antennas.

    Added System Bandwidth and Uplink Channel Number to the parameters provided to the DUT
    Driver for Configuration and Handover.

    Added support for stop-on-fault and retry.
    
    Added Comment property.

    Added Frequency Error result in ppm.
    
    Added support for DUT antenna configuration to be defined by the DUT driver.
    
    Added support to send test point settings to a result writer (on request).
    
    Added support for Aeroflex logging.


Version 1.6.0
=============
    Fixed an analysis instability issue

    Fixed some cosmetic issues in the GUI


Version 1.5.0
=============
    Fixed issue caused by the misuse of the analysis library when more than one device is being tested.

    Improved error reporting when there is a failure to configure the Dut Connection Control.


Version 1.4.0
=============
    Added direct support for the limit checking that was previously done by the GUI. This will allow test plans
    created by the PXI Maestro GUI that included limit checking to perform the limit checking even when not run from
    within the PXI Maestro GUI. This requires version 1.4 or later of the PXI Maestro core.


Version 1.3.0
=============

    Requires PXI Maestro V2.0.0 to be installed.

    Improved the reliability of execution aborts.

    Improved error reporting 


Version 1.2.0
=============

    Fixed an issue whereby error codes associated with a failure to attempt to 
    make a measurement for a test point (such as a device setup failure) were 
    not written to the result metadata when a result writer DLL was used.

    Updated the Spectral Flatness measurement to perform the measurement according 
    to the 3GPP TS 36.521-1 V10.1.0.

    Added the ability make power supply current measurements whilst other tests are 
    being performed when a suitable power supply plugin dll is utilised.

Version 1.1.0
=============
    First release.

    This release implements the EVM Equalizer spectrum flatness measurement is 
    implemented in accordance to section 6.6.2.4 of 3GPP TS 36.521-1 V8.4.0 2009-12),
    User Equipment (UE) conformance specification Radio transmission and reception.
    A future version of this library will include an update to implement measurement 
    according to 3GPP TS 36.521-1 V10.1.0 (2012-03), User Equipment (UE) conformance 
    specification Radio transmission and reception.

     When this happens the following changes will be made:
        The Following API functions will become obsolete and will return an error
        code:
            afPtLteFdd_SpectrumFlatness_Upper_UserLimits_Set
            afPtLteFdd_SpectrumFlatness_Upper_UserLimits_Get
            afPtLteFdd_SpectrumFlatness_Upper_UserLimits_GetLength
            afPtLteFdd_SpectrumFlatness_Lower_UserLimits_Set
            afPtLteFdd_SpectrumFlatness_Lower_UserLimits_Get
            afPtLteFdd_SpectrumFlatness_Lower_UserLimits_GetLength
            afPtLteFdd_SpectrumFlatness_Lower_PassFail_Get
            afPtLteFdd_SpectrumFlatness_Upper_PassFail_Get
            afPtLteFdd_SpectrumFlatness_Slot_LowerLimit_GetTrace
            afPtLteFdd_SpectrumFlatness_Slot_LowerLimit_GetTraceLength
            afPtLteFdd_SpectrumFlatness_Slot_LowerLimit_GetNumTraces
            afPtLteFdd_SpectrumFlatness_Slot_UpperLimit_GetTrace
            afPtLteFdd_SpectrumFlatness_Slot_UpperLimit_GetTraceLength
            afPtLteFdd_SpectrumFlatness_Slot_UpperLimit_GetNumTraces

        In addition calling the afPtLteFdd_SpectrumFlatness_Mode_Set function with
        the mode value set to 'afPtLteFdd_sfmFlatnessUserDefined' will result in 
        an error.
        